Advertisement number: 3210549 Promote Restore Edit Delete
Back
1 / 5
TIMER CONTROLLER 12V-24V 24 HOURS WITH 5 OPTIONS
600 MKD
The price is fixed
28.06.2020 11:17

Kochani / Kochani

Item condition
New

- I'M SELLING TIMERS FOR TIME REGULATION OF VARIOUS DEVICES ON 12V-24V WITH 5 OPERATIONS OF YOUR CHOICE. - SPECIFICATIONS: - Wide power supply voltage 5.0V ~ 60V; The mode can be set for multiple time periods, it can reach 5 time periods; With alarm function. Mode introduction: OPE: relay close time point, CLE: turn off time point Time period: PE-1 ~ PE-5 5 time periods (OPE to CLE is a time period) ----: function protected P-1 : The relay closes or pulses out every day until the OPE time point, and the relay closes or pulses out at the CLE time point. P-2: set the day, in the time point OPE when the relay is closed or the output pulse, in CLE the time point when the relay is turned off or the output pulse P-3: Set the date of the month, in the time point OPE when the relay is closed or the output pulse, to CLE the time point when the relay is off or the output pulse P-4: Set date 1 to date 2, start every day at the time point OPE, rotate the time point of CLE, relay action or output pulse P-5: As with P-4, cannot set only the month   How to set the time? In the running time of the interface, press the DOWN key for a while: Step 1: Select the time period: PE-1 ~ PE-5 Press UP and DOWN to select; Step 2: Press the SET button to select the mode: P-1 ~ P-5 (Set this time period in the corresponding mode) by pressing the UP and DOWN buttons. ("----" means to block this time period) Note: Each time period can be repeated from "----", Q-1 ~ Q-5 is optional; For example, you can allow five time periods to operate in P-1 mode at the same time, or allow Time Period 1 to operate in P-1 mode, Time Period 2 to operate in P-2 mode, and so on. Step 3: After the selection is complete, press the SET button to enter the time period setting interface, set the time period interface, press the SET button to change the parameter, the time point "OPE", "CLE" end point , "dAE" date information; Step 4: After setting the parameters to exit the settings, press the SET button for 2 seconds to release, automatically check the parameter settings to save the parameters, return to the time to run the interface; if the parameter is wrong, "ERR" prompt (for example, stop time or date <= start time or date), return to the parameter setting interface; Additional features: Each "time period" can be set individually In the specific parameter setting interface (after the second step), press the STOP button to switch the output mode OUT. - WE SEND VIA CARGO EXPRESS

Category: Business and activities, Machine tools / Professional tools

For sale from:

INKUBATORI I OPREMA-DIGITALNI MERNI INSTRUMENTI I VLAGOMERI
Verified Advertiser
070-607-455 077-735-790
Send an email to the advertiser

PM2.5 DETEKTOR ZA MERENJE CESTICKI-KVALITET NA VOZDUHOT

1600 MKD

TERMOMETAR ANALOGEN ZA PECKI ILI PECENA HRANA DO 300C

1500 MKD

Welcome to Reklama5.mk

In order to make the Reklama5 easier and more accessible to use, we use cookies on our website. By surfing on reklama5.mk you agree to use cookies. You can find detailed information at Cookie Policy

I agree